AED 200,00
Handpiece DCD System Cooling Fan is a specialized replacement cooling fan for compatible Candela GentleMax Pro Dynamic Cooling Device (DCD) handpiece assemblies. This compact ventilation component is associated with cooling the internal DCD handpiece arrangement and supporting the airflow required by the handpiece design.
The Candela GentleMax Pro operator’s manual identifies an internal fan in DCD handpieces that helps cool the handpiece and reduce bubble-related faults. The fan operates alongside a separate serviceable air filter positioned in the handpiece ventilation arrangement.
Designed for professional laser maintenance and technical servicing, the Handpiece DCD System Cooling Fan is a replacement component for clinics and laser service specialists maintaining compatible Candela handpiece assemblies.
Levant Technology supplies professional Candela laser spare parts, DCD handpiece components, cooling fans, handpiece covers, electronic accessories, and aesthetic laser equipment replacement parts in the UAE.
Handpiece DCD System Cooling Fan is an internal ventilation component associated with the Dynamic Cooling Device handpiece of compatible Candela GentleMax Pro laser systems.
Professional aesthetic laser equipment contains several interconnected assemblies, including the laser heads, power electronics, optical delivery system, handpiece components, and cooling equipment.
The DCD delivery system is used to deliver a controlled cryogen spray to the treatment area before the corresponding laser pulse.
In compatible DCD handpiece designs, a small fan is incorporated into the handpiece assembly.
The fan provides local airflow to help cool the handpiece and reduce bubble-related faults.
A separate air filter is positioned in front of the fan to capture dust entering the ventilation arrangement.
The Handpiece DCD System Cooling Fan belongs to this localized handpiece ventilation system.
It is an individual replacement fan rather than a complete DCD handpiece, cryogen valve, air filter, cooling canister, or laser delivery system.
Specialized Candela Handpiece Component
The fan is associated with the internal DCD handpiece ventilation arrangement of compatible Candela GentleMax Pro equipment.
Supports Local Handpiece Cooling
A correctly matched and functioning fan provides airflow according to the handpiece’s intended ventilation design.
Relevant to Bubble-Fault Diagnostics
The GentleMax Pro operator’s manual identifies the DCD handpiece fan as a component that helps cool the handpiece and reduce bubble-related faults.
Focused Replacement Solution
Replacing an individual fan may be appropriate when a qualified technician confirms that the installed cooling fan has failed and the remaining handpiece components are suitable for continued use.
Useful for Professional Handpiece Maintenance
The component can form part of technical servicing involving the DCD handpiece’s internal ventilation and electrical assemblies.
The Candela GentleMax Pro is a professional aesthetic laser platform combining two laser technologies:
The equipment supports different optical delivery and epidermal cooling configurations.
One available configuration is Candela’s Dynamic Cooling Device (DCD).
DCD technology delivers a controlled cryogen spray to the skin before the laser pulse, according to the selected spray and delay parameters.
This cooling arrangement is designed to help protect the epidermis during appropriate laser treatments.
The DCD handpiece contains specialized mechanical and electrical components associated with cryogen delivery and laser operation.
Compatible Standard and Specialty DCD handpieces also contain an internal cooling fan.
The Handpiece DCD System Cooling Fan supports the handpiece’s local ventilation arrangement.
It does not independently produce cryogen, determine laser fluence, control the laser wavelength, or generate the treatment beam.
The DCD handpiece combines several functions within a compact assembly.
The optical delivery arrangement directs laser energy toward the treatment area.
The cryogen delivery components provide the designated epidermal cooling spray.
Separate electrical and mechanical components support handpiece operation.
The internal cooling fan serves an additional function.
It moves air through the corresponding ventilation pathway to help manage the thermal conditions inside the handpiece.
The GentleMax Pro operator’s manual specifically identifies this fan in both Standard and Specialty DCD handpiece configurations.
The manual also describes a removable air filter located in front of the fan.
DCD Handpiece Cooling Fan
An active ventilation component used to move air through the designated handpiece pathway.
DCD Handpiece Fan Filter
A filtration component positioned in front of the fan to capture airborne particles.
DCD Handpiece Air Vent
An opening associated with the designed ventilation pathway.
Handpiece Body
Provides the mechanical enclosure for the compatible handpiece components.
DCD Cryogen Delivery Components
Provide the designated cryogen spray function as part of the DCD system.
Handpiece Optical Components
Deliver laser energy through the corresponding optical pathway.
These components have different roles within the handpiece.
The Handpiece DCD System Cooling Fan is an active ventilation component rather than an air filter, optical component, or cryogen delivery valve.
The cooling fan and fan filter are closely related, but they perform different functions.
DCD Handpiece Cooling Fan
An electrically powered component that moves air through the relevant handpiece ventilation pathway.
DCD Handpiece Fan Filter
A separate filtration medium located in front of the fan.
The fan generates airflow, while the filter captures dust and airborne debris according to its design.
A dirty or obstructed fan filter may affect airflow even when the fan itself is functioning.
Likewise, replacing or cleaning the filter does not repair a mechanically or electrically defective fan.
The GentleMax Pro operator’s manual provides user maintenance instructions for cleaning and replacing the DCD handpiece fan filter.
The internal fan itself is a different component and requires appropriate professional servicing.
The Handpiece DCD System Cooling Fan should not be confused with the DCD Handpiece Fan Filter.
Candela GentleMax Pro equipment contains different ventilation components.
DCD Handpiece Cooling Fan
A small active ventilation component located inside the compatible DCD handpiece assembly.
DCD Handpiece Fan Filter
A filtration component located near the handpiece’s internal cooling fan.
GentleMax Pro Main System Air Filter
A separate air filtration component associated with the ventilation system of the main laser equipment housing.
Main Equipment Ventilation Fans
Associated with moving air through the corresponding equipment cooling and heat exchange pathways.
These components operate in different locations.
The DCD handpiece cooling fan is not the same as the air filter installed on the rear panel of the main laser system.
Similarly, a machine cabinet ventilation fan is not automatically interchangeable with a handpiece fan.
The correct component depends on the intended installation location and the original electrical and mechanical specifications.
The Dynamic Cooling Device uses different components to perform its cooling functions.
DCD Handpiece Cooling Fan
Provides localized airflow within the compatible handpiece.
DCD Cryogen Spray Valve
Associated with controlling cryogen delivery within the relevant DCD arrangement.
Cryogen Canister
Stores the cryogen used by the DCD system.
Cryogen Delivery Line
Provides the designated cryogen pathway between relevant system components.
DCD Spray Nozzle
Directs the cryogen spray toward the intended treatment area.
The fan cools the handpiece, while the cryogen delivery components perform the epidermal spray cooling function.
A fan replacement does not automatically correct a damaged spray valve, blocked nozzle, depleted cryogen canister, or delivery-line fault.
The Handpiece DCD System Cooling Fan should therefore be identified as a handpiece ventilation component rather than a cryogen spray control component.
Candela GentleMax Pro supports different epidermal cooling configurations.
Dynamic Cooling Device (DCD)
Uses controlled cryogen spray delivered by the corresponding DCD handpiece.
Air Cooling Compatible (ACC)
Uses a compatible external air cooling device to supply refrigerated air to the treatment area through the appropriate accessory.
DCD Handpiece Cooling Fan
Provides localized ventilation inside the DCD handpiece itself.
These cooling functions are not interchangeable.
The DCD handpiece fan does not supply the refrigerated treatment air used by an ACC handpiece.
It also does not replace the external air cooling machine.
The Handpiece DCD System Cooling Fan is intended for the corresponding DCD handpiece ventilation application.
Candela GentleMax Pro equipment supports different DCD delivery configurations.
Standard DCD Handpiece
A handpiece configuration incorporating the corresponding cryogen delivery components, optical pathway, local cooling fan, and fan filter.
Specialty DCD Handpiece
A handpiece configuration intended for compatible specialty delivery arrangements, also incorporating a local cooling fan and serviceable fan filter.
Large Spot Specialty DCD Configuration
A delivery arrangement supporting designated larger treatment spot sizes according to the equipment configuration.
Although these DCD handpieces share related ventilation functions, their internal fan dimensions, mounting arrangements, and electrical connections should not automatically be assumed identical.
The Handpiece DCD System Cooling Fan must be matched to the actual installed handpiece.
Levant Technology can assist with identifying the appropriate replacement using the original fan and handpiece details.
The Handpiece DCD System Cooling Fan is primarily associated with compatible Candela GentleMax Pro DCD handpiece assemblies.
Related DCD handpiece fan configurations may be used in selected Candela Gentle Pro family equipment, including:
However, these are related equipment families rather than a confirmed universal compatibility list for the supplied fan.
Compatibility depends on the handpiece generation, fan dimensions, electrical rating, connector, and mounting design.
A replacement intended for one DCD handpiece configuration may not fit another.
Compatibility with Candela GentleMax Pro Plus must also be verified separately.
The correct component should be identified using the original fan reference and installed handpiece configuration.
The Candela GentleMax Pro operator’s manual explains that the cooling fan helps cool the DCD handpiece and reduce bubble faults.
A bubble-related indication may lead technicians to inspect the handpiece ventilation arrangement.
Potential areas of investigation can include:
However, a bubble fault does not automatically establish that the cooling fan has failed.
The handpiece may require additional inspection to identify the actual source of the warning.
A functioning fan may not resolve a fault caused by a different DCD component.
The Handpiece DCD System Cooling Fan is a potential replacement component when professional diagnostics confirm that the fan requires replacement.
Handpiece ventilation components may require inspection or replacement during professional laser equipment maintenance.
A qualified technician may investigate the internal fan when identifying:
These symptoms may involve other handpiece components and do not automatically indicate that the fan is defective.
Dust accumulation in the filter, damaged wiring, or other handpiece faults may produce similar symptoms.
A matching replacement fan may be used when qualified technicians confirm that the original component requires replacement.
The GentleMax Pro operator’s manual identifies the DCD handpiece fan filter as a serviceable component.
The manual recommends cleaning the fan filter periodically and when a handpiece bubble message appears.
This maintenance instruction relates to the fan filter, not to disassembly or replacement of the internal electric fan.
The fan and surrounding ventilation arrangement should be inspected by qualified service personnel when abnormal operation is suspected.
A blocked filter should be addressed according to the applicable operator instructions.
A defective internal fan may require separate professional maintenance.
The Handpiece DCD System Cooling Fan is a replacement component rather than a cleaning accessory or disposable filtration medium.
The Candela Dynamic Cooling Device uses a designated cryogen delivery arrangement to provide epidermal cooling.
The fan supports the handpiece’s local temperature management but does not independently generate cryogen spray.
Successful DCD operation depends on several components, including the cryogen supply, delivery lines, nozzle, valve, handpiece electronics, and machine control system.
If a cooling spray problem is present, technicians should identify the actual cause before replacing individual components.
A fan replacement may be appropriate when the fan is defective.
However, the replacement does not independently restore a blocked cryogen line, repair a failed valve, or correct every spray delivery problem.
The Handpiece DCD System Cooling Fan should therefore be used for its designated ventilation function.
Professional Candela handpieces are specialized assemblies containing optical, electrical, and mechanical components.
Their condition is relevant to safe and reliable laser operation.
During technical servicing, qualified personnel may inspect the handpiece enclosure, electrical connections, ventilation components, optical pathway, and DCD-related assemblies.
A damaged fan may require replacement if the component no longer operates according to the intended design.
The surrounding filter and ventilation openings should also be assessed during relevant maintenance.
However, replacing the fan does not independently guarantee improved laser output, eliminate all DCD faults, or extend the operating life of the entire system.
The handpiece should be evaluated as a complete assembly according to the applicable manufacturer service requirements.
Handpiece cooling fans can have similar appearances while using different physical dimensions, electrical ratings, and mounting configurations.
For an accurate replacement-part enquiry, useful information includes:
Levant Technology can provide available product details and assist technicians with identifying the correct DCD handpiece cooling fan.
Confirming the original fan specifications before purchase is important because a fan with a similar appearance may use a different voltage, connector, or mounting configuration.
Handpiece DCD System Cooling Fan should be installed by a qualified professional laser service technician experienced with Candela DCD handpiece assemblies.
Professional laser delivery systems contain sensitive optical components, electrical connections, and cryogen delivery arrangements that require specialized servicing.
The GentleMax Pro operator’s manual lists the handpiece fan filter as user-serviceable but does not identify the internal fan itself as a routine operator-replaceable component.
Internal fan replacement should therefore follow the applicable professional service procedures rather than ordinary handpiece cleaning instructions.
The replacement fan must match the original electrical and mechanical configuration.
Qualified technicians should verify the fan’s mounting, electrical connections, airflow direction, and operation according to the equipment requirements.
The handpiece ventilation components and related DCD functions should be checked after servicing.
The complete delivery system should undergo the appropriate operational and safety verification before returning to clinical use.
Levant Technology supplies professional aesthetic laser equipment spare parts and replacement components for clinics, dermatology centers, biomedical engineers, and laser service specialists throughout the UAE.
Our product range includes DCD handpiece cooling fans, fan filters, handpiece covers, cryogen-related accessories, electronic components, optical parts, and professional laser equipment spare parts.
For customers maintaining Candela GentleMax Pro equipment, our team can assist with fan identification, available configurations, pricing, and ordering enquiries.
What is Handpiece DCD System Cooling Fan?
It is a replacement internal ventilation fan associated with the Dynamic Cooling Device handpiece of compatible Candela GentleMax Pro laser equipment.
Which laser machine is this fan associated with?
The product is primarily listed for the Candela GentleMax Pro laser platform.
What does DCD mean?
DCD stands for Dynamic Cooling Device, a Candela epidermal cooling system that uses controlled cryogen spray.
What is the purpose of the DCD handpiece cooling fan?
The fan provides local airflow to help cool the handpiece and reduce bubble-related faults.
Does the fan deliver cryogen onto the skin?
No. Cryogen spray is delivered through the DCD system’s designated cryogen components.
Does the fan control the cryogen spray duration?
No. Spray duration and delay settings are controlled through the equipment’s corresponding DCD system.
Does the fan provide refrigerated air for treatment?
No. The fan cools the handpiece internally. Refrigerated treatment air is associated with compatible external ACC cooling arrangements.
Is this the same as the DCD handpiece fan filter?
No. The fan is an active electrical component, while the fan filter is a separate filtration medium.
Does this product include the fan filter?
The included components must be confirmed with Levant Technology before ordering.
Is this the same as the GentleMax Pro main air filter?
No. The main air filter belongs to the laser cabinet ventilation system, while this fan is associated with the DCD handpiece.
Do Standard DCD handpieces contain cooling fans?
Yes. The GentleMax Pro operator’s manual identifies an internal fan in the Standard DCD handpiece.
Do Specialty DCD handpieces contain cooling fans?
Yes. The operator’s manual also identifies a cooling fan in the Specialty DCD handpiece.
Does the same replacement fan fit Standard and Specialty DCD handpieces?
Compatibility must be confirmed using the actual fan dimensions, electrical characteristics, and mounting arrangement.
What is a DCD handpiece bubble fault?
It is a fault indication associated with conditions in the corresponding DCD handpiece system. The manufacturer identifies the cooling fan as a component that helps reduce bubble-related faults.
Does a bubble fault always mean the cooling fan is defective?
No. Bubble-related issues can involve multiple handpiece or DCD components and require proper technical diagnosis.
Can a dirty fan filter cause ventilation problems?
Dust accumulation or blockage may restrict the intended airflow through the handpiece ventilation pathway.
Can the DCD fan filter be cleaned?
Yes. The GentleMax Pro operator’s manual includes cleaning instructions for the serviceable DCD handpiece fan filter.
Is the internal cooling fan user-serviceable?
The operator’s manual identifies the fan filter, rather than the internal fan, as a routine user-serviceable item. Fan replacement should be performed by qualified service personnel.
Does this fan fit GentleLase Pro?
Related DCD handpiece fan configurations may be available for GentleLase Pro equipment, but the supplied component must be matched to the installed handpiece.
Can it be used with GentleYAG Pro?
Compatibility depends on the original handpiece fan reference and the equipment’s DCD configuration.
Is it compatible with GentleMax Pro Plus?
Compatibility with GentleMax Pro Plus must be verified separately using the actual handpiece and fan specifications.
What is the operating voltage of this fan?
Levant Technology can provide available electrical specifications for the supplied component.
What are the fan dimensions?
The exact fan dimensions and mounting configuration are available on enquiry.
Does the fan include an electrical connector?
The supplied wiring and connector details should be confirmed before ordering.
What is the fan part number?
Levant Technology can provide available component identification details and part-number information.
Is this a genuine Candela OEM fan?
OEM status and manufacturer details should be confirmed with Levant Technology before ordering.
Can a defective DCD cooling fan be replaced?
Yes. A correctly matched replacement may be installed when qualified technicians confirm that the original fan requires replacement.
Does replacing the fan eliminate all bubble faults?
No. Bubble-related faults may involve other DCD handpiece components or operating conditions.
Does replacing the fan restore cryogen spray delivery?
Not automatically. Cryogen delivery depends on the relevant DCD valve, supply, nozzle, connections, and control components.
Does the cooling fan improve laser power?
The fan is a handpiece ventilation component and does not independently increase laser output.
How often should the cooling fan be replaced?
Replacement depends on the condition of the fan and the applicable service requirements. No universal fixed replacement interval should be assumed.
Who should install the replacement fan?
Installation and handpiece verification should be performed by a qualified professional laser service technician.
Can I order Handpiece DCD System Cooling Fan in the UAE?
Levant Technology handles enquiries for professional Candela DCD cooling fans, handpiece ventilation components, and aesthetic laser spare parts in the UAE.
Looking for a Handpiece DCD System Cooling Fan for your Candela GentleMax Pro equipment?
Levant Technology supplies DCD handpiece cooling fans, handpiece fan filters, cryogen delivery accessories, handpiece covers, optical components, electronic replacement parts, and professional aesthetic laser spare parts for clinics and technical service specialists across the UAE.
Our team can assist with handpiece fan identification, available electrical configurations, product specifications, pricing, and ordering.
Explore our laser spare parts collection for more Candela handpiece components and professional laser equipment replacement parts.
Interested in Handpiece DCD System Cooling Fan? Contact Levant Technology on WhatsApp for pricing, availability, and orders.
AED 1.800,00
AED 500,00 Original price was: AED 500,00.AED 350,00Current price is: AED 350,00.
AED 500,00
AED 1.500,00
AED 650,00
AED 500,00
AED 715,00
AED 300,00
AED 5.000,00
AED 1.400,00
Write a Review